Air Bag Testing – Did You Know?
According to NFPA 1936, all lifting bags that are 15 years old or older must be removed from service and destroyed. This is due to the natural degradation of rubber, the material used in all rescue lifting bag systems, which has a safe service life of no more than 15 years. However, actual lifespan can be much shorter depending on use and environmental exposure.
NFPA 1937 provides an opportunity to establish standard operating procedures that ensure lifting bags remain in optimal condition. For instance, Chapter 7 of the standard—Technician Maintenance (7.1.2) and Inspection Frequency (7.1.2.1)—requires annual testing of lifting bags by a certified, factory-trained technician. In addition, users are required to conduct inspections after each use and on a monthly basis.
Together, these measures reduce risk, extend equipment reliability, and help maintain the highest level of safety.
Scope and Context of NFPA 1936
-
Originally published in 1999 and revised (notably in 2005 and 2010), NFPA 1936 establishes minimum design, performance, testing, and certification requirements for powered rescue tools—such as spreaders, cutters, rams, and combination tools.
-
In its most recent cycles, the standard has expanded to include rescue air bag systems (i.e., lifting bags), aiming to set performance testing and verification criteria for these tools.